Home > News > About Plug

About Plug

  • Uruguay plug more information-Ningbo Qiaopu Electric Co., Ltd.

    Uruguay plug more information Range:South America Region: Uruguay Uruguay Description: three poles similar to India Current: 15A Voltage: 220V-230V Frequency: 50Hz Conversion plug: South Africa the standard / India marked The confirmation Index: ★ ★ South Africa / India standard plug Description: India and South Africa standard plug to BS 546 India / SABS 164-1 South Africa manufacturing standards implementation, standard changes come on the basis of the British Standard 546 (1962 British BS 1363 plug standard). BS 546 standard is also used in the southern parts of Africa (such as Ghana, Kenya, Nigeria), Middle East (Kuwait, Qatar), Nepal and parts of Asia and the Far East in some areas. Pins for the three cylindrical, the diameter of the ground than zero fire two the plug electrical parameters 15A/250VAC. Note: Indian standard plug is not forced to accept the British Standards Institute's certification, detailed consultation with the local power standard export equipment to India. More information from the Ministry of Ningbo qiaopu Electric Co., Ltd. [View Details]
  • Venezuela plug detailed information-Ningbo Qiaopu Electric Co., Ltd.

    Venezuela plug detailed information Range:South America Region: Guatemala Guatemala Description: The three-pole, similar to the U.S. Current: 15A Voltage: 120V Frequency: 60Hz The conversion plug: American Standard The confirmation Index: ★ ★ ★ North American standard plug (with ground) Description: North American standard plug NEMA 1-15,5-15,5-20,6-15,6 - 20P plug standard manufacturing. Management to accept NEMA (National Electrical Manufacturers Association) in the U.S. American standard flat line plug cylindrical middle ground plug and UL certification. The plug and socket standards in Canada, CSA C22.2-No. 42. NEMA 5 - 15P style plug used in countries of the west coast of Mexico, Japan, Korea, Taiwan, Central America, Colombia, Venezuela, Ecuador and South America region. The electric power system in the developing world are usually not grounded. Outlet network is not recommended to cut off the ground prong, eliminate safety ground is not safe. But the remedies of the ground wire, the electrical parameters of the North American standard plug: 2.5A-15A/125VAC. UL and CSA certified plug. Can be equipped with a variety of sizes and types of cables, mainly used for data transmission, such as power server, computer data storage systems, network equipment, industrial equipment. Plug standard 15A/125VAC popularity the most current 20A/250VAC less. American standard the injection power cord and plug in the medical institutions use the S & P will be easy to install, have dedicated medical grade plug system. One side of the wire is the amount of current as 10A IEC-60320 connectors. 15A/125VAC maximum output rating. Equipment manufacturers require the power cord of the device is controlled by UL and CSA standards. In order to coordinate with the changes in the specifications of the IEC standards and UL amendment IT equipment standards. UL certification (60950 and CAN / CSA C22.2 No. 60950) and medical equipment standards (UL Certified 60601 and CAN / CSA C22.2 No. 60601), UL certified 60950 and CAN / CSA C22.2-60950 Joint Declaration, the power cord The ground wire must be green and yellow of the color line. The UL certification 60601 and CAN / CSA C22.2 No. 60601 requires ground for the green / yellow zero line for the light blue, FireWire brown. There are indications that, UL and CSA shall not rigid enforcement of these requirements. In both cases, it is recommended to use the the polarity identifying colors (brown, blue, green / yellow) color-coded cables, UL and CSA certification requirements to accept. Before this, some equipment manufacturers to be able to distinguish between the North American power cord polarity color coding, namely black, white, green, universal international standard color coding, namely red, blue, green / yellow. Now, UL and CSA certified equipment manufacturers need a the unified standard power line identification (FireWire - brown, zero line - blue ground - green / yellow). More information from the Ministry of Ningbo qiaopu Electric Co., Ltd. [View Details]
  • Guatemala plug detailed information-Ningbo Qiaopu Electric Co., Ltd.

    Guatemala plug detailed information Range:South America Region: Guatemala Guatemala Description: The three-pole, similar to the U.S. Current: 15A Voltage: 120V Frequency: 60Hz The conversion plug: American Standard The confirmation Index: ★ ★ ★ North American standard plug (with ground) Description: North American standard plug NEMA 1-15,5-15,5-20,6-15,6 - 20P plug standard manufacturing. Management to accept NEMA (National Electrical Manufacturers Association) in the U.S. American standard flat line plug cylindrical middle ground plug and UL certification. The plug and socket standards in Canada, CSA C22.2-No. 42. NEMA 5 - 15P style plug used in countries of the west coast of Mexico, Japan, Korea, Taiwan, Central America, Colombia, Venezuela, Ecuador and South America region. The electric power system in the developing world are usually not grounded. Outlet network is not recommended to cut off the ground prong, eliminate safety ground is not safe. But the remedies of the ground wire, the electrical parameters of the North American standard plug: 2.5A-15A/125VAC. UL and CSA certified plug. Can be equipped with a variety of sizes and types of cables, mainly used for data transmission, such as power server, computer data storage systems, network equipment, industrial equipment. Plug standard 15A/125VAC popularity the most current 20A/250VAC less. American standard the injection power cord and plug in the medical institutions use the S & P will be easy to install, have dedicated medical grade plug system. One side of the wire is the amount of current as 10A IEC-60320 connectors. 15A/125VAC maximum output rating. Equipment manufacturers require the power cord of the device is controlled by UL and CSA standards. In order to coordinate with the changes in the specifications of the IEC standards and UL amendment IT equipment standards. UL certification (60950 and CAN / CSA C22.2 No. 60950) and medical equipment standards (UL Certified 60601 and CAN / CSA C22.2 No. 60601), UL certified 60950 and CAN / CSA C22.2-60950 Joint Declaration, the power cord The ground wire must be green and yellow of the color line. The UL certification 60601 and CAN / CSA C22.2 No. 60601 requires ground for the green / yellow zero line for the light blue, FireWire brown. There are indications that, UL and CSA shall not rigid enforcement of these requirements. In both cases, it is recommended to use the the polarity identifying colors (brown, blue, green / yellow) color-coded cables, UL and CSA certification requirements to accept. Before this, some equipment manufacturers to be able to distinguish between the North American power cord polarity color coding, namely black, white, green, universal international standard color coding, namely red, blue, green / yellow. Now, UL and CSA certified equipment manufacturers need a the unified standard power line identification (FireWire - brown, zero line - blue ground - green / yellow). More information from the Ministry of Ningbo qiaopu Electric Co., Ltd. [View Details]
  • Suriname plug detailed information-Ningbo Qiaopu Electric Co., Ltd.

    Suriname plug detailed information Range:South America Region: Suriname Suriname Description: Diodes, similar to Germany Current: 2.5A Voltage: 230V Frequency: 50Hz Conversion plug: European standard (2.5A) The confirmation Index: ★ ★ ★ European plug (no ground) Description: European plug (no ground) manufacturing standard CEE 7/16. Two cylindrical ground, a span of 19mm cylinder diameter 4mm, used in most European countries: Germany, Austria, Switzerland, Italy, the Netherlands, Belgium, France, Spain, Portugal, Denmark, Norway, Sweden, Finland, Greece, Turkey Israel, Poland, the Czech Republic, Slovakia, Hungary, Romania, Bulgaria and Russia. Also used in the Middle East, most of Africa, South America and many developing countries. To enter the EU countries imported equipment must be strictly in accordance with the EU standard power cord and plug and socket CE certification, this is a must, mandatory. Note: European standard wall outlet universal standard. French standard plug ground is a single-level embedded the outlet grounding prong protruding, very special. More information from the Ministry of Ningbo qiaopu Electric Co., Ltd. [View Details]
  • St. Vincent plug more information-Ningbo Qiaopu Electric Co., Ltd.

    St. Vincent plug more information Range:South America Area: St. Vincent St.Vincent Description: three poles similar to the United Kingdom Current: 13A Voltage: 230V Frequency: 50Hz The conversion plug: British standard The confirmation Index: ★ ★ British standard plug (a triangle plug) Description: British standard plug (a triangle plug) execution, also known as the British standard BS 1363 manufacturing standards. British official plug standard since 1962 has been in use BS 1363. British standard is also used in the British colonial countries, such as Ireland, Hong Kong, Malaysia and Singapore. British standard plug is a triangle, rectangular columnar section, withstand high-current, the safest plug one of many plug standards. British standard power outlet the protection door design, you can prevent the foreign body insertion or prevent mis-insertion, more secure and reliable. The plug and socket is forced to accept the British ASTA test certification bodies and electrical testing. British standard plug electrical parameters 3-13A/250VAC More information from the Ministry of Ningbo qiaopu Electric Co., Ltd. [View Details]
  • St. Pierre & Miquelon (Fr.) plug detailed information-Ningbo Qiaopu Electric Co., Ltd.

    St. Pierre & Miquelon (Fr.) plug detailed information Range:South America Region: St. Pierre St. Pierre & Miquelon (Fr.) Description: three poles similar to France Current: 16A Voltage: 230V Frequency: 50Hz Conversion plugs: French standard The confirmation Index: ★ French standard plug (Embedded grounded) Description: French standard plug (embedded grounding) performed CEE 7 manufacturing standards common to France and Belgium. French standard plug similar to the European standard plug, the plug is cylindrical; but the ground there is a difference between the French standard socket raised ground prong. 10A 250VAC electrical parameters More information from the Ministry of Ningbo qiaopu Electric Co., Ltd. [View Details]
  • Saint Louis(St. Louis) plug the detailed information-Ningbo Qiaopu Electric Co., Ltd.

    Saint Louis(St. Louis) plug the detailed information Range:South America Region: St. Louis, Saint Louis Description: three poles similar to the United Kingdom Current: 13A Voltage: 230V Frequency: 50Hz The conversion plug: British standard The confirmation Index: ★ ★ ★ British standard plug (a triangle plug) Description: British standard plug (a triangle plug) execution, also known as the British standard BS 1363 manufacturing standards. British official plug standard since 1962 has been in use BS 1363. British standard is also used in the British colonial countries, such as Ireland, Hong Kong, Malaysia and Singapore. British standard plug is a triangle, rectangular columnar section, withstand high-current, the safest plug one of many plug standards. British standard power outlet the protection door design, you can prevent the foreign body insertion or prevent mis-insertion, more secure and reliable. The plug and socket is forced to accept the British ASTA test certification bodies and electrical testing. British standard plug electrical parameters 3-13A/250VAC More information from the Ministry of Ningbo qiaopu Electric Co., Ltd. [View Details]
  • Salvador plug detailed information-Ningbo Qiaopu Electric Co., Ltd.

    Salvador plug detailed information Range:South America District: El Salvador El Salvador Description: diode similar to that of the United States Current: 15A Voltage: 120V Frequency: 60Hz Conversion plugs: American Standard (no ground) The confirmation Index: ★ ★ ★ North American standard plug (no ground) Description: North American standard plug NEMA 1-15,5-15,5-20,6-15,6 - 20P plug standard manufacturing. Accept the management of NEMA (National Electrical Manufacturers Association) and UL certification in the United States, the American standard flat line plug. The plug and socket standards in Canada, CSA C22.2-No. 42. NEMA 5 - 15P style plug used in countries of the west coast of Mexico, Japan, Korea, Taiwan, Central America, Colombia, Venezuela, Ecuador and South America region. The electric power system in the developing world are usually not grounded. Outlet network is not recommended to cut off the ground prong, eliminate safety ground is not safe. But the remedies of the ground wire, the electrical parameters of the North American standard plug: 2.5A-15A/125VAC. UL and CSA certified plug. Can be equipped with a variety of sizes and types of cables, mainly used for data transmission, such as power server, computer data storage systems, network equipment, industrial equipment. Plug standard 15A/125VAC popularity the most current 20A/250VAC less. American standard the injection power cord and plug in the medical institutions use the S & P will be easy to install, have dedicated medical grade plug system. One side of the wire is the amount of current as 10A IEC-60320 connectors. 15A/125VAC maximum output rating. Equipment manufacturers require the power cord of the device is controlled by UL and CSA standards. In order to coordinate with the changes in the specifications of the IEC standards and UL amendment IT equipment standards. UL certification (60950 and CAN / CSA C22.2 No. 60950) and medical equipment standards (UL Certified 60601 and CAN / CSA C22.2 No. 60601), UL certified 60950 and CAN / CSA C22.2-60950 Joint Declaration, the power cord The ground wire must be green and yellow of the color line. The UL certification 60601 and CAN / CSA C22.2 No. 60601 requires ground for the green / yellow zero line for the light blue, FireWire brown. There are indications that, UL and CSA shall not rigid enforcement of these requirements. In both cases, it is recommended to use the the polarity identifying colors (brown, blue, green / yellow) color-coded cables, UL and CSA certification requirements to accept. Before this, some equipment manufacturers to be able to distinguish between the North American power cord polarity color coding, namely black, white, green, universal international standard color coding, namely red, blue, green / yellow. Now, UL and CSA certified equipment manufacturers need a the unified standard power line identification (FireWire - brown, zero line - blue ground - green / yellow). More information from the Ministry of Ningbo qiaopu Electric Co., Ltd. [View Details]
  • Pitcairn Is. (U.K.) plug more information-Ningbo Qiaopu Electric Co., Ltd.

    Pitcairn Is. (U.K.) plug more information Range:South America Region: Pitcairn Pitcairn Is. (U.K.) Description: three poles similar to the United Kingdom Current: 13A Voltage: 230V Frequency: 50Hz The conversion plug: British standard The confirmation Index: ★ ★ British standard plug (a triangle plug) Description: Pitcairn plug more information British standard plug (a triangle plug) execution, also known as the British standard BS 1363 manufacturing standards. British official plug standard since 1962 has been in use BS 1363. British standard is also used in the British colonial countries, such as Ireland, Hong Kong, Malaysia and Singapore. British standard plug is a triangle, rectangular columnar section, withstand high-current, the safest plug one of many plug standards. British standard power outlet the protection door design, you can prevent the foreign body insertion or prevent mis-insertion, more secure and reliable. The plug and socket is forced to accept the British ASTA test certification bodies and electrical testing. British standard plug electrical parameters 3-13A/250VAC More information from the Ministry of Ningbo qiaopu Electric Co., Ltd. [View Details]
  • Nicaragua plug detailed information-Ningbo Qiaopu Electric Co., Ltd.

    Nicaragua plug detailed information Range:South America Region: Peru Peru Description: The three-pole, similar to the U.S. Current: 15A Voltage: 120V Frequency: 60Hz The conversion plug: American Standard The confirmation Index: ★ ★ ★ North American standard plug (with ground) Description: Nicaragua plug detailed information North American standard plug NEMA 1-15,5-15,5-20,6-15,6 - 20P plug standard manufacturing. To accept NEMA (National Electrical Manufacturers Association) in the middle of the U.S. American standard flat line plug cylindrical grounded plugs management and UL certification. The plug and socket standards in Canada, CSA C22.2-No. 42. NEMA 5 - 15P style plug used in countries of the west coast of Mexico, Japan, Korea, Taiwan, Central America, Colombia, Venezuela, Ecuador and South America region. The electric power system in the developing world are usually not grounded. Outlet network is not recommended to cut off the ground prong, eliminate safety ground is not safe. But the remedies of the ground wire, the electrical parameters of the North American standard plug: 2.5A-15A/125VAC. UL and CSA certified plug. Can be equipped with a variety of sizes and types of cables, mainly used for data transmission, such as power server, computer data storage systems, network equipment, industrial equipment. Plug standard 15A/125VAC popularity the most current 20A/250VAC less. American standard the injection power cord and plug in the medical institutions use the S & P will be easy to install, have dedicated medical grade plug system. One side of the wire is the amount of current as 10A IEC-60320 connectors. 15A/125VAC maximum output rating. Equipment manufacturers require the power cord of the device is controlled by UL and CSA standards. In order to coordinate with the changes in the specifications of the IEC standards and UL amendment IT equipment standards. UL certification (60950 and CAN / CSA C22.2 No. 60950) and medical equipment standards (UL Certified 60601 and CAN / CSA C22.2 No. 60601), UL certified 60950 and CAN / CSA C22.2-60950 Joint Declaration, the power cord The ground wire must be green and yellow of the color line. The UL certification 60601 and CAN / CSA C22.2 No. 60601 requires ground for the green / yellow zero line for the light blue, FireWire brown. There are indications that, UL and CSA shall not rigid enforcement of these requirements. In both cases, it is recommended to use the the polarity identifying colors (brown, blue, green / yellow) color-coded cables, UL and CSA certification requirements to accept. Before this, some equipment manufacturers to be able to distinguish between the North American power cord polarity color coding, namely black, white, green, universal international standard color coding, namely red, blue, green / yellow. Now, UL and CSA certified equipment manufacturers need a the unified standard power line identification (FireWire - brown, zero line - blue ground - green / yellow). More information from the Ministry of Ningbo qiaopu Electric Co., Ltd. [View Details]

Contact Us

  • Contact Person:

    Gavi Chen
  • Tel:

    +86-0574-62166266
  • +86-15888180299
  • Fax:

    +86-0574-62179799
  • E-mail:

    gavi@plug9.com
点击这里给我发消息
点击这里给我发消息